Views: 0 Author: Site Editor Publish Time: 2021-12-16 Origin: Site
World machinery can supply hyraulic shearing machines with Estun E21 NC system. NC system is easy for operation and programmable for multi-steps shearing. This article is introducing the solution of maulfunction of the NC system.
1)The electrode of power supply terminal is connected error; please see the information of power nameplate.
2)Voltage is too low.
3)Electrical outlet is not connected.
1)Two motors are reversed. Reconnect.
1)Check whether mechanical part has been locked or slider returns to upper dead center.
2)Check whether the motor wiring is connected well.
1)Check whether high-low speed signal has been sent or motor power is too small.
2)Check whether the parameter of distance conversion is correct.
1)Check when slider is on upper dead center, STEP terminal is connected to +24V or not.
1)Check when slider is on upper dead center, STEP terminal is connected to +24V or not.
1)Check whether encoder cable is connected or not.
2)Check whether the motor-direction wiring is correct (X+, X-, A+, A-, G+, G-).
1)Check whether encoder wiring is correct or encoder cable is connected well.